Picasso is the beginning of the revolutionary line of products to come from AMD LASERS™, LLC. Its sleek design, superior features and rock bottom pricing will transform the ENT arena for years to come. |
| See Comparison Chart published by Ortho Town: |
 |
Dr.ron Kaminer
Masters of Laser Dentistry |
|
|
| |
 |
 |
0.1 - 7.0 Watts |
 |
Touch screen interface |
 |
Fiber with retractable reel |
 |
Continuous or pulse modes |
 |
8 Customizable presets |
 |
Adjustable aiming beam |
 |
Multiple language menu: |
| |
English,
Spanish,
Portuguese,
Russian,
Chinese
,Korean,
Japanese |
 |
Compatible with US and international power outlets; 110/240/ volt compatible |
 |
3-year warranty |
|
| |
|
|
|
| |
| |
| |
| |
| |
| |
| |
| |
| Main laser application benefits: |
Good therapeutic effects (reduces oedema, relives pain, combats inflammation, accelerates tissue repair, improves physiological function).
Simple treatment methods and short therapy duartion.
Painless, user-friendly and aseptic operations, eliminates the possibility of infection.
Good acceptance by patients, especially by children and elderly people.
Very good economic effects for the clinic - makes clinic competitive.
Simple and effective treatment of disease that are impossible to be treated by conventional methods. |
| |
| |
| |
| |
| |
| |
| CO2 LASER Model CTL-1401 |
 |
|
 |
| 10W, 15W |
|
20W, 25W, 30W |
|
| The most gentle among well-known lasers for effective non-contact and bloodless cutting, vaporisation and coagulation of soft tissue. It offers distinct advantages for outpatient clinics, ambulatory care centers and private medical practices. It provides power and performance in a compact design, is easy transported from room to room and is clinically versatile serving the diverse needs of multiple specialties. Laser surgeons performing Gynecology, ENT, Dentistry, Dermatology and Aesthetic Surgery precedures will all find CTL-1401 as invaluable tool. It can be successfully applied in other medical fields, whenever precision, hemostasis, patient's comfort and reputation of consultation room are appreciated |
| |
| Basic technical parameters |
| Laser type |
carbon dioxide (CO2), sealed-off, RF excited
|
| Wavelength |
10600nm, far IR highly absorbed by water and biological tissues |
| Mode structure |
TEM |
| Radiation power on tissue |
from 1W to 12W, regulated in steps of 1W (optionally from 1W to 25W, regulated in steps of 1W) |
| Operation mode |
continuous wave (c.w.), single and repeat pulse |
| Pulse duration |
from 0.1s to 9.9s in steps of 0.1s with inter-pulse interval from 0.1s to 9.9s in steps of 0.1s |
| Laser controller |
built-in microprocessor, regulated and displayed power, operation mode and pulse duration |
| Aiming beam |
lighting of operation field by red beam diode laser (650nm, 5mW) |
| Shooting control |
foot switch |
| Delivery system |
5 mirror articulated arm (optionally 6- or 7-mirror spring-balanced articulated arm) |
| Spot size |
from 0.1mm to 0.3mm for fixed focus handpieces
from 0.4mm to 3mm for variable focus handpiece for respective focal distances |
| Standard accessories |
- fixed focus handpiece with focal length 125mm with one straight tip, one 90 and one 120 angled mirror tips
- laser safety glasses |
| Optional accessories |
- fixed focus handpieces with focal length 50mm or 200mm, variable focus handpieces
- wall arm with metal support for convenient laser storage and increase of movement freedom
- micromanipulator adaptable to a wide variety of microscopes
- computer patterns generating scanner with at least 5 different shapes programmed, size and scanning speed regulated easily from scanner's handpiece
- smoke evacuator |
| Cooling system |
integrated, air forced |
| Power supply |
ingle phase (220-230)V, 50Hz |
| Dimensions |
470mm x 250mm x 145mm |
| Weight |
13kg |
| Safety |
laser made according to the international standards IEC 601.1 and IEC 825 |
|
| |
| Basic usage features: |
It is truly portable, very light, extremely robust and can be handcarried without difficulty. A truly multi-disciplinary system, very affordable, cost-effective for wide range of surgical applications, designed with small outpatients' clinics and private consultation rooms in mind.
The CO2 laser beam is the only laser beam which is entirely absorbed by the water. It seals off blood vessels, lymph vessels and nerve endings as the laser incises providing clear, dry view of the operative field. Working with a clear field reduce the time required for many procedures. Visualisation is further improved since colourless safety lenses are best-suited for eye protection against radiation of 10600nm wavelength.
The operations with CO2 laser reduce blood loss to enhance infection control. The laser radiation can heat the surface of tissue to temperatures that can kill bacteria allowing sterilisation of the surgical site and minimising post operative infection.
The post surgical course is less painful and hemorrhage-free. The CTL-1401 works without traumataising surrounding or underlying tissue, so patients have minimal swelling and edema, and report and absence of pain in most cases.
The small spot size and minimal absorption depth allows CO2 laser to provide an exceptional level of precision. With proper selection of power and delivery mode it is possible to remove a sinle layer of cells. The laser can quickly and accurately cut, vaporise and coagulate tissue, allowing the user precise control to achieve desired results.
With scanner handpiece you can attain a new standard of quality in the treatment of large-area skin defects with the CTL-1401 laser. Not only is therapy accelerated, the ablation is more even. Computer pattern generator provides unparlleled ease of use, exceptional mobility and fast, effecient transitions during procedures. Medical professionals can resurface skin in highly controlled manner with greater confidence and reliability, ensuring consistent and reproducible ablations. When using the scanner with proper laser energy settings, the risk of thermal damage is minimised, resulting in faster healing and greater patient satisfaction.
The CTL-1401 is easy to use and its constant performance and power output are controlled and maintained unchanged in time by the sophisticated electronics the sytem is equipped with. With the help of the computer control the various operating modes can be adjusted easliy and quckly (continous wave mode, single and repeat pulse mode).
Simple, safe opartion due to well-illuminated indicators and built-in microprocessor control providing easy choice of desired parameters adjusted by easy-care membrane keypad.
It is electrically very safe, does not contain any higher voltage than 24V. The laser tube has been sealed using the modem hard sealing technique. The typical life of that RF excited tube is over 20.000 hours. It means for a doctor no maintenance and further investment for many years.
Spacial lightweight 5-mirror articulated arm supported by additional freedom movement of wall arm enables performing high accurate surgical treatment without fatigue for the surgeon. Due to this fact the laser can be used easily both in the free-hand and endoscopic surgery. The artciulated arm can be partially folded into the laser.
The laser can be adopted through a micromanipulator to most of surgical microscopes and colposcopes. Used in conjuction with an operating microscope the CO2 laser provides precise ablation of minimal treatment influence on the surrounding tissue. The possibility of focusing and defocusing in the range from 200 to 400mm enables treatment of much wider group of diseases in gynecology and ENT. |
| |
| Applications: |
CO2 laser is the answer to medicine's continuing search for surgical alternatives that are minmally invasive and less traumatic to the patient. Features, clinical performance and a wide range of accessories make the CO2 laser versatile and affordable tool for outpatient clinic and private offices. The CTL-1401 meets clinical needs in these new environments in amultitude of applications in dermatology and aesthetic surgery, ENT and denstistry, gynecology and proctology and many other specialities. Laser scanner for the uniform char-free single layer ablation of large tissue areas in dermatology, colposcopes for cervical, vaginal and vulval accurate micro-surgery in gynecology, angled mirror handpiece tips for bloodless procedures in oral surgery, variable, long focal handpiece with backstop for uvulopalatplasty in ENT and beam spot size as small as 0.1mm for precise incisions in podiatry extend the well established advantages of CO2 surgical laser system.
ENT - polyps, nodules, cordal lesions, cordectomy, arytenoidectomy, stenosis and webs, carcinoma in-situ, papillomas, adenomas, tonsillectomy, turbinectomy, myringotomy, stapedectomy, glossectomy
|
|
| |
| Laser accessories: |
The CO2 laser system Model CTL-1401 is supported by the wide selection of specially designed accessories for free-hand surgery. Its lightweight articulated arm offers superior maneuvrability of the steralizable handpiece. It features a unique weigthless spring-balanced 6- or 7-mirror arm. Not balanced 5-mirror articulated arm is additionaly supported by special wall arm to even increase freedom of movement. Fixed focus handpieces of different focal length (50, 127, 200mm) or variable focal handpieces providing convenient defocusing and easy spot size selection (from 0.4mm to 3mm) are completely rotatable after treading into arm. Handpieces are available with either straight tips indicating the exact focal point or backstop tips for safety and tissue manipulation or angled mirror tips (90o and 120o) enabling access to confined areas. Handpieces are also equipped with air flow port providing a clean barrier protecting optics from contamination.
The laser pattern generating scanner is a unique new treatment modality providing precisely-controlled, homogenous, cahr-free ablation. Computer controlled mirrors rapidly displace a focused beam over a trajectory which uniformly covers a tissue area of size that varies from 2 x 2mm2 up to 30 x 30mm2. A surgeon also chooses the scanning speed and the pattern most apropriate to the type of procedure to be performed. The red aiming beam indicates the oulines of pattern chosen directly from the scanner's handpiece. The typical shapes are: square, rectangular, triangle, hexagon and circle.
CO2 laser microsurgery requires precisely controlled operation with no damage to surrounding tissue. Advancedmicromanipulator senable to couple the laser articulated arm to a variety of stereomicroscopes and colposcopes. The focal distance of the micromanipulator can be adjusted within working distances of 200mm to 400mm. The zoom optics provide the surgeon with a wide range of spots sizes which can be regulated continuously and the diameter may reach the value of minimum 0.4mm and maximum 7.0mm. The prallax-free construction of the micromanipulator guarantees that aiming beam is perfectly coaxial with the joystick-controlled CO2 laser beam and both beams coincide with the optical axis of the microscope. Being on the same focal plane of a proprietary parbolic mirror the aiming and CO2 beam are always the same diameter.
Working with laser is entirely safe, as long as you apply adequate antilaser eyewear for your sight. If you want to secure sufficient eye protection, take advantage of our professional Safety glasses Model CTL-2133 specially designed to protect against CO2 laser radiation. Such colourless eyewear offers ideal balance between effective attenuation of harmful radiation (protection level as high as L10) and, at the same time, allow maximum luminous transmittance (as high as 90%) of light for the wearer to see clearly. Two types of ergonomic frames are available. The spectacles with adjustable temples for a comfortable matching to any face and goggles to be worn over a prescription glasses.
|
|
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| Main laser application benefits: |
Painless, very precise and safe therapy
Conducting a new kind of treatments - impossible to be done by classical methods
Silent instruments, working without vibrations
Microsurgery without scalpel and stitches
Attractive financially for the dentist - saves on materials, increases the number of clients, makes his surgery more competitive
|
| |
ENT LASER Model CTL-1601 Erbium: YAG Laser
FOR NON-CONTACT TOOTH DRILLING AND PAINLESS OSTEOTHOMY |
 |
|
Very effective, painless and non-contact hard tooth tissue treatment. Specially selected, optimal set of laser parameters and skilled hand of the modern dentist make this instrument unique in comparison with standard dental tools in many treatments. The instrument is equipped with handpiece and exchangeable, easy to sterilise straight and angled tips. Its specific construction and technical parameters enables to carry out treatments that were very difficult to be realised so far. |
|
| |
| Basic technical parameters |
| Laser type |
Er: YAG, solid state laser |
| Wavelength |
2940nm, medium IR, optimal for effective tooth enamel and dentine removal |
| Operation mode |
pulse, guarantees minimum pain and maximum effeciency of work |
| Pulse width |
(150-200)ľs, optimal for non-thermal interaction |
| Pulse energy |
from 100mJ to 500mJ in steps of 50mJ |
| Average radiation power on tissue |
from 0.1W to 5W, depends on pulse energy and repetition rate |
| Repetition rate |
regulated at the range of 0.1Hz up to 10Hz, provides tissue removal rate at the range of 0.5mm3/s up to 3mm3/s |
| Aiming beam |
lighting of operation field by red beam diode laser (650nm, 5mW) |
| Shooting control |
one- or two-position foot switch |
| Basic accessories |
straight and angled tips, with handpiece connected to the articulated arm which delivers laser beam to the operation field |
| Additional accessories |
water spray system which about two times accelerates tissue removal |
| Cooling system |
inner, water-to-air |
| Power supply |
single phase, (220-230)V, 50Hz |
| Dimensions |
laser head: 470mm x 250mm x 140mm cooling system: 470mm x 250mm x 530mm |
| Weight |
laser head: approx. 17kg cooling system: approx. 25kg |
| Safety |
class I electrical safety according to standards IEC 820 and PN-91/T-06701,
class IV laser safety according to standards IEC 825 and PN91/T-06700 |
|
| |
| Basic usage features: |
Effectively replaces a dental engine in many treatments.
Painlessly removes enamel as well as dentine decay changes and clears the fillings.
Precisley removes tooth caries without damaging of surrounding tissue. After cavity clearing by laser beam, acid etching is not necessary (while it is essential after using dental engine), so filling sticks very well.
Non-contact therapy - only laser beam reaches the treated tooth.
Precise using of laser with clearly visible operation field excludes the possibility of uncovering dental pulp. If this situation occurs, it is not dangerous, because damage has only a short-time mechanical stroke character, without causing the dental pulp necrosis.
In many experiments with purposeful or incidental uncover of dental pulp by laser pulse no evidence of thermal pulp inflammatory has been observed.
Forming of rough enamel surface by laser provides increased stickiness of material filling tooth tissue. Degree of stickness is comparable or even higher than acid etching process.
Does not make micro-cracks on the tooth enamel |
| |
| The main laser application benefits: |
Painless, non-contact, very precise and safe treatments.
High prescision minimises posibility of damage.
Shorter time and higher efficiency of treatment.
Ideal instrument for children and nervous patients due to silent work and low invasive method.
Very attractive financially for dentists: saves on materials, increases the number of clients. |
| |
| |
| |
| |
| Basic technical parameters |
| Laser type |
diode (semiconductor) laser |
| Wavelength |
905nm, near IR |
| Operation mode |
pulse |
| Pulse width |
200ns |
| Repetition rate |
regulated in a wide range from 1Hz to 10000Hz |
| Peak power |
regulated in the range 0÷30W |
| Average radiation power on tissue |
regulated in the range 0÷60mW, fine adjustment on control panel, depending on repetition rate |
| Laser controller |
built-in microprocessor |
| Displayed functions |
peak power [W], average power [mW], enegry dose [J], total applied energy dose [J], therapy time duration [min., sec.] |
| Application handpice |
interchangeable and heat-resistant tips with different shapes and sizes |
| Additional accessories |
protective spectacles and goggles robuts carrying case |
| Power supply |
single phase, (220-230)V, 50Hz |
| Power consumption |
14W
|
| Controller size |
228mm x 216mm x 76mm |
| Weight |
1.2kg |
| Safety |
Laser made according to the international standards IEC-601 and IEC-825. It is equipped with: target indicator, built-in power meter, remote interlock connection and key switch. It is CE marked product. |
|
| |
| Basic usage features: |
Digital programming of peak and average power, frequency of pulses, dose of energy.
Full keypad operation for fast and simple programming.
Long-lived laser diodes are adjusted on 50% of its maximal power to increase laser reliability.
Interchangeable fibre optic tips for both internal and external applications. All tips are autoclavable and can be cleaned easily using a disinfectant.
The variable accessories are available, guaranteed to suit the individual area of applications (tips, glasses, carrying cases).
High accuracy of frequency selection.
Separate digital power meter for monitoring actual output.
A built-in target light makes highly accurate and specific treatment.
Up-to 30W laser power and up to 10000Hz frequency give shorter treatment time and a large therapeutic working depth.
Simplicity and easy-to-use operation make this instrument suitable even for those just strating to work with therapy methods.
The design and performance of laser therapy units are regulated by the international standards IEC-601 and IEC-825. This high quality product is CE marked. |
|
|
| |
| |
|
|
|